This walkthrough covers a routine sediment or carbon cartridge change in a under-sink or in-line housing. It is the service visit you can do yourself, from the first valve to the last log entry. If your unit has UV lamps, electronics, or a softener tank, follow that unit's manual instead, because those steps differ.

Before you start

Open the manual and find the exact replacement cartridge for your housing. Gather a bucket, towels, gloves, and the housing wrench if your model uses one. Check the manual for the lubricant it names for the seals. Use only the type it lists, because some petroleum products can damage plastic and rubber parts.

Step by step

First, shut the supply. Close the inlet valve on the supply line, or set the bypass as the manual describes if your unit has one. Then open the lowest cold faucet in the house and let it run until the flow stops. This releases the pressure trapped in the housing.

Second, place the bucket under the housing and loosen it. Some housings twist off by hand, and others need the wrench. Expect a little water to drip out. Lower the housing carefully and empty any water left inside.

Third, remove the old cartridge and look at it before you throw it away. Note the color, any slime, grit, or odor, and whether the cartridge looks compressed or cracked. This is useful information for the log and for deciding whether your usual change interval is right for your water.

Fourth, inspect the O-ring and the housing. Check the ring for cracks, flat spots, or grit. Wipe out the housing bowl and rinse it if it is dirty. Lubricate the ring lightly with the type the manual names, then seat it in its groove.

Fifth, install the new cartridge. Match the orientation to the arrow or label on the cartridge and the housing. If the manual says to wet the cartridge before installing, do that first. Set it straight, then close the housing. Tighten by hand to the point the manual describes. Overtightening can crack the housing.

Sixth, restore the supply slowly. Open the inlet valve a little at a time, and check the housing for drips. Then open the lowest cold faucet and let air clear from the line until the water runs steady without sputtering.

Seventh, flush the new cartridge. Run cold water for the time the manual gives, and discard the first water if it tells you to. Carbon cartridges often release fine particles at first, so do not skip this step.

What to check and record

Confirm the housing is dry after an hour or so, and check that the water tastes and looks normal. Write a log entry with the cartridge model, what you saw in the old one, the time the job took, and any problem. A short entry like this is the most useful thing you can give the next person who opens that housing.

If anything does not fit, stop and call the service provider or the manufacturer rather than forcing it. A housing that will not close is usually a seating problem, and forcing it is how a simple change becomes a leak.